Security engineer — Harlow, Essex, Hertfordshire & LondonMon–Fri, 8am–5pmk.smith@ever-guard.uk07793547694

EVER-GUARD

Recent work

Photographs from recent jobs. These are our own installations, not stock photography.

Registered installer
  • Paxton registered installer
  • Ajax registered installer
  • Texecom registered installer
  • Pyronix registered installer
  • Public liability insured
  • 10-year workmanship guarantee
  • Tavcom BTEC Diploma
  • IPAF licensed

Intruder alarm installations

The photographs below are from recent alarm work — detectors, door and window contacts, sounders and control panels. What they have in common is placement: the difference between a system that works and one that false-alarms is almost always where the devices went, not what they cost.

  • Motion detector fitted at high level above a stairwell landing, positioned to cover the hallway without catching the stairs directly.
    Motion detector fitted at high level above a stairwell landing, positioned to cover the hallway without catching the stairs directly.
  • Intruder alarm control panel with a keyswitch below it, mounted at the entry point of a domestic property.
    Intruder alarm control panel with a keyswitch below it, mounted at the entry point of a domestic property.
  • Flush door contact fitted to an internal door frame, aligned so the door closes without fouling the magnet.
    Flush door contact fitted to an internal door frame, aligned so the door closes without fouling the magnet.
  • Internal sounder fitted in a ceiling corner where it carries through the property.
    Internal sounder fitted in a ceiling corner where it carries through the property.
  • Ceiling-level detector covering an open-plan kitchen and living area.
    Ceiling-level detector covering an open-plan kitchen and living area.
  • Contact fitted to a glazed roof light — a common weak point that standard alarm packages leave uncovered.
    Contact fitted to a glazed roof light — a common weak point that standard alarm packages leave uncovered.
  • Discreet contact on an opening roof light, fitted to the frame rather than the glass.
    Discreet contact on an opening roof light, fitted to the frame rather than the glass.
  • Window contact fitted to a sash window, sited to stay out of the sight line from inside the room.
    Window contact fitted to a sash window, sited to stay out of the sight line from inside the room.

We are adding photographs of recent CCTV, access control and door entry installations to this page. If you would like to see examples of a particular type of work before deciding, ask and we will send them over.

Next step

Have it looked at properly

Tell us the property and what you want covering. We survey before we quote, and the engineer who walks round the building is the one who installs the system.

Direct
07793547694
Email
k.smith@ever-guard.uk
Hours
Mon–Fri, 8am–5pm
Based
Harlow, CM19